Registered Customer Login
Search
STRIP-IT™ - Instructions to apply using Foam Applicator - Part of the PACE ACBD System® sanitation program

Foam Applicator Kits
  • Standard Kit part #: HPU10001
Standard Foam Applicator
  • Stainless Steel Kit part #: HPU10002 (3.4 gpm )
  • Stainless Steel Kit part #: HPU10003 (5.7 gpm )
Stainless Steel Foam Applicator
Click  HERE  to view or download Stainless Steel specification sheet!
Parts included:
  • Foamer Nozzle (shown)
  • Quick-connect Coupling (shown connected on right)
  • Strainer / Filter Check Valve
  • Plastic Tubing
  • Tubing Clamp
*Assembly tools are NOT provided!
The Foam Applicator Kit or its individual parts are available directly from  PACE  or from one of our product  distributors.
*Distributors may have different part #s.
NOTE 1:
  • The foam applicator should be used with a pressure washer delivering a minimum of  1000 psi  and a maximum of  3200 psi  (maximum of  4000 psi  for stainless steel models).
Click  HERE  for a full-size 2-minute instructional video with audio
on how to assemble the Foam Applicator Kits.
NOTE 2:
  • To avoid clogging the internal parts of the foam applicator, use clean water for the pressure washer and ensure that a strainer / filter like the one supplied with the Foam Applicator Kit is attached to the end of the plastic tubing.
STRIP-IT™ - Heavy-duty acid-based phosphate-free cleaner!
NOTE 3:
  • Use safety equipment and clothing recommended in the  MSDS (Material Safety Data Sheet)  for the handling of this product.

Directions: (* applies to Standard Kit only)

* For Stainless Steel Kit application
- refer to the Specification Sheet  HERE.

  1. Prepare sufficient use-solution by diluting  1 part  of  STRIP-IT™   to  3 parts  of water.  Mix thoroughly.
  2. Fill a container such as a backpack sprayer tank with use-solution.
  3. Connect the foam nozzle to the pressure washer wand tip using the quick connection.
  4. Using plastic tubing, connect the container to the barbed fitting on the foam nozzle.
  5. Fully open the valve on the foam nozzle.  This will deliver an approximately  1 : 32 dilution  of  STRIP-IT™   to the surface being cleaned.
  6. Activate the wand trigger.  Under these conditions the foam produced should resemble shaving foam.
  7. Apply foam evenly to all surfaces to be cleaned.
  8. Allow to penetrate for about  5 minutes  then disconnect the foam nozzle and rinse surfaces with clean water at high pressure.

For instructions on the use of our products
in your specific application,